Question

Load bearing or not (diagrams and images!)?


So I'm looking at removing a pantry and creating a doorway into a garage space that is going to be my new den/office. The pantry is moving into the laundry area where we took out a folding table. The issue here is that framing for the pantry seems to have a double 2x4 at the top which a DIY book indicated that said wall could be load bearing (I know nothing about this stuff). It seemed really odd that there would be any load on these pantry walls, so that's why I decided to throw a post up here before having a structural engineer come out (or a contractor).

I've made two quick visio diagrams based on the assessor sketch and my own observations/measurements and then included a picture of the pantry door frame which shows some of the framing. The red arrows in the level1_original indicate the walls I need to work on, the level1_new shows how the walls will be changed.

If anyone can help me here I would really appreciate it!
Attached Thumbnails
Load bearing or not (diagrams and images!)?-100_9806.jpg   Load bearing or not (diagrams and images!)?-level1_new.jpg   Load bearing or not (diagrams and images!)?-level1_original_comments.jpg  

amclint is offline   Reply With Quote
Old 11-17-2008, 04:57 AM   #2
BUILDER / REMODELING CONT
 
buletbob's Avatar
 
Join Date: May 2008
Location: LONG ISLAND N.Y
Posts: 1,543
Default

Load bearing or not (diagrams and images!)?


I doubt the wall your looking to remove is full load bearing, usually with a layout like yours your ceiling or floor joists would be lapped on the center wall just above the basement girder. is there a way for you to see if the beams are lapped on the wall your going to removed. if the beams are running front to back I do not see a problem in what you plan to do. unless they are lapped on the walls in question. BOB

buletbob is offline   Reply With Quote
Old 11-17-2008, 06:17 AM   #3
Lic. Builder/GC/Remodeler
 
AtlanticWBConst.'s Avatar
 
Join Date: May 2006
Location: New England
Posts: 7,556
Default

Load bearing or not (diagrams and images!)?


I agree with bob (Based on the layouts that you provided).

I must say, that is one big structural header tho.

As stated, you still need to check and make sure that the area, is definitely not supporting any joists.
AtlanticWBConst. is offline   Reply With Quote
Old 11-17-2008, 07:58 AM   #4
Member
 
joed's Avatar
 
Join Date: Mar 2005
Location: Welland, Ontario
Posts: 7,454
Default

Load bearing or not (diagrams and images!)?


Without knowing the direction of the joists above it next to impossible to be sure.
joed is online now   Reply With Quote
Old 11-17-2008, 08:06 AM   #5
Lic. Builder/GC/Remodeler
 
AtlanticWBConst.'s Avatar
 
Join Date: May 2006
Location: New England
Posts: 7,556
Default

Load bearing or not (diagrams and images!)?


Quote:
Originally Posted by joed View Post
Without knowing the direction of the joists above it next to impossible to be sure.
Actually, the drawings that the OP supplied to show the main carrying beams, allow the viewer to assume the locations of the joists (based on modern residential building & construction design).
Couple that with the overall design of the house's footprint; the rafter/truss locations can be assumed as well. This allows the estimation of where (direction) the joists are running.

Again, that is based on viewing the PO supplied details.

However, no responsible person on this site, will tell a poster, to go ahead an cut-away, unless they could see the area in person. That would be irresponsible on our part. Thus, the best and safest method, would really be, to have a licensed or certified individual look at the area, in person - to OK it for the work planned.
AtlanticWBConst. is offline   Reply With Quote
Old 11-17-2008, 08:38 AM   #6
First-time Home Owner
 
Join Date: Jun 2007
Location: Pittsburgh, PA
Posts: 44
Default

Load bearing or not (diagrams and images!)?


Curious, what's above that space?

It's worth it to hire a structural engineer. Previous owners at our house didn't before taking down a wall that didn't appear to be load-bearing. (Honestly, I would have made the same mistake; it really seemed to not be doing anything.) It was actually distributing a lot of weight though, and the second floor sank 3 inches because they removed it.
ciera is offline   Reply With Quote
Old 11-17-2008, 08:51 AM   #7
Newbie
 
Join Date: Nov 2008
Posts: 3
Default

Load bearing or not (diagrams and images!)?


This is the first floor of a 2 floor home, below it is a basement with a big I beam going through the middle.

I think the stuctural header threw me, can anyone tell me if the DIY book has any validity in stating the two 2x4's stacked at the top of the wall means load bearing?
amclint is offline   Reply With Quote
Old 11-17-2008, 08:58 AM   #8
Newbie
 
Join Date: Nov 2008
Posts: 3
Default

Load bearing or not (diagrams and images!)?


Let me be clear, I wasn't expecting anyone to tell me it's safe to cut away just whether or not these walls I highlighted in red could be load bearing or if that would be really unlikely given how houses are built (I just don't know these things). It seems odd to me to put weight there, but it may be incidental if the floor joists for the 2nd level are just running across them? Anyway thanks for looking at the post, I've got a call into the old homeowner who incidentally is a contractor and built the place so I'm hoping he'll remember and be able to tell me
amclint is offline   Reply With Quote
Old 11-17-2008, 10:50 AM   #9
BUILDER / REMODELING CONT
 
buletbob's Avatar
 
Join Date: May 2008
Location: LONG ISLAND N.Y
Posts: 1,543
Default

Load bearing or not (diagrams and images!)?


Quote:
Originally Posted by amclint View Post
This is the first floor of a 2 floor home, below it is a basement with a big I beam going through the middle.

I think the stuctural header threw me, can anyone tell me if the DIY book has any validity in stating the two 2x4's stacked at the top of the wall means load bearing?
Those double 2x4's are going to be on a no bearing and bearing wall that is how those walls are framed. BOB
buletbob is offline   Reply With Quote
Old 11-17-2008, 01:27 PM   #10
Member
 
joed's Avatar
 
Join Date: Mar 2005
Location: Welland, Ontario
Posts: 7,454
Default

Load bearing or not (diagrams and images!)?


Quote:
Originally Posted by AtlanticWBConst. View Post
Actually, the drawings that the OP supplied to show the main carrying beams, allow the viewer to assume the locations of the joists (based on modern residential building & construction design).
I see that now. I mis read the post and thought the dashed line were the wall needed to be removed. My guess is that the small pantry needed to be moved in not load bearing and if it is, moving the short distance shown in the drawing will not be a problem. Build the new wall before you remove the old one.

joed is online now   Reply With Quote
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off





Top of Page | View New Posts

Copyright © 2003-2014 Escalate Media. All Rights Reserved.