RocknRoller 06-19-2007 10:01 AM

Bathroom remodel snafu
 
Bathroom is gutted, am installing new fixtures for tub/shower, toilet, and sink. Also installing new drywall ( green board ) , ceramic tile for shower surround and floor.
The problem right now is getting the depth inside the wall for the water valve. The instructions provided are useless ( who writes that stuff ? ).
I had screwed the valve to 2x4 but that was to much, then tried 1x4 which looked like it would work. put up the drywall piece I cut for it and now it is too shallow .
the only thing that comes to my mind is building up with 1/2 in. material behind the valve which will be difficult but not impossible. Any sugestions would be very welcome.

NateHanson 06-19-2007 11:30 AM

You're having trouble mounting the shower valve at the right distance back from the finished wall?

Why not just mount your 1x4 a little closer to the finished wall? Not as far back between the studs.

Am I misunderstanding the question?

The 1x4 doesn't need to be all the way back in the stud-space.

AtlanticWBConst. 06-19-2007 12:30 PM

Quote:

Originally Posted by RocknRoller (Post 49640)
Bathroom is gutted, am installing new fixtures for tub/shower, toilet, and sink. Also installing new drywall ( green board ) , ceramic tile for shower surround and floor.
The problem right now is getting the depth inside the wall for the water valve. The instructions provided are useless ( who writes that stuff ? ).
I had screwed the valve to 2x4 but that was to much, then tried 1x4 which looked like it would work. put up the drywall piece I cut for it and now it is too shallow .
the only thing that comes to my mind is building up with 1/2 in. material behind the valve which will be difficult but not impossible. Any sugestions would be very welcome.

Use a 2x4 or 2x6 (even better) place on the "flat" between the studs. Also, DON'T USE GREEN BOARD for the walls and tile. Use cement board.

skymaster 06-19-2007 03:21 PM

Atlantic: AMEN BROTHER NO GREEN BOARD:thumbsup: Cement board for tile backer and the new paperless drywall for the rest of the bathroom. Darn I cant think of the name of it either, think USG has it out, its even in the Borg boxes :huh:
You know what it is fer shure. AHHHHHHHHH DENSHIELD DATS ITmighr b spelled wrong but dats its name.
JackM

AtlanticWBConst. 06-19-2007 05:15 PM

Quote:

Originally Posted by skymaster (Post 49690)
Atlantic: AMEN BROTHER NO GREEN BOARD:thumbsup: Cement board for tile backer and the new paperless drywall for the rest of the bathroom. Darn I cant think of the name of it either, think USG has it out, its even in the Borg boxes :huh:
You know what it is fer shure. AHHHHHHHHH DENSHIELD DATS ITmighr b spelled wrong but dats its name.
JackM

Georgia Pacific DENSARMOR (Paperless Drywall)
This stuff:

http://www.gp.com/build/product.aspx?pid=4899

http://www.stopfeedingmold.com/

skymaster 06-19-2007 05:49 PM

:laughing: :thumbsup: :yes: SEE ATLANTIC I KNEW YOU KNEW DAT
jACK