chilangopolaco 04-29-2008 09:09 AM

siding repair
 
I have replaced 7 sheets of rotten siding. I have used hardi pannels and hardi trims. I have a dillemma whether I should go up and cover the sticking out flashing with 1X6 and ugly seams with 1X4 following the pattern at the bottom ? Is there some air circulation issue (can flashing in the siding be covered ?).

before
http://i282.photobucket.com/albums/k...o/000_0009.jpg

After

http://i282.photobucket.com/albums/k...o/IMG_1621.jpg
http://i282.photobucket.com/albums/k...o/IMG_1622.jpg
http://i282.photobucket.com/albums/k...o/IMG_1623.jpg
http://i282.photobucket.com/albums/k...o/IMG_1624.jpg


Also I was planning to cover those ugly seam with 1X4 on the rest of the siding. The siding is not rotten at the bottom so I can leave it as is, just add 1X4 along the flashing and seams .. Is it a good idea ?

http://i282.photobucket.com/albums/k...o/IMG_1619.jpg
http://i282.photobucket.com/albums/k...o/IMG_1620.jpg
http://i282.photobucket.com/albums/k...o/IMG_1618.jpg

Termite 04-30-2008 11:58 AM

You're asking for trouble by not flashing the 1x4's and horizontal seams as one unit. I don't see any z-bar flashing at the top of the sheet of hardie board.

Never cover flashing with 1x4's or anything else. Incorporate them into the flashed system if you want them.