How to deal with obstruction when insulating pipes?


I'm insulating hot water heating pipes (black iron pipe) in my basement using 1"-thick-wall jacketed fiberglass tubes. At one point one of the pipes passes right under a 2 foot wide A/C duct. The tube won't fit at the top of the pipe since it's too close to the duct. What's the best way to insulate that section? Do a relief cut that's so deep that there's almost no insulation left at the top, but still retaining the jacket (which would probably deform due to almost no insulation left)? Or cut out a inch or two wide, two foot long section at the top of the pipe? Or ... ? Moving the heating pipe, or moving the A/C duct, is NOT an option. Thanks.

Rav is offline   Reply With Quote
Join DIYChatroom.com

Join the #1 DIY Forum Today - It's Totally Free!

DIYChatroom.com - Are you about to start a new home improvement task and need some help? Do you need advise on what products to buy? Or maybe you can give others some advice? No matter where you fit in you'll find that DIY Chatroom is a great community to join. Best of all it's totally free.

Join DIYChatroom.com - Click Here
JOIN FOR FREE


Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death. DIYChatroom.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any home improvement task!
Old 01-11-2012, 08:15 PM   #2
Member
 
Join Date: Jul 2008
Location: Canada (s/w ON.)
Posts: 2,294
Default

How to deal with obstruction when insulating pipes?


Quote:
Originally Posted by Rav View Post
I'm insulating hot water heating pipes (black iron pipe) in my basement using 1"-thick-wall jacketed fiberglass tubes. At one point one of the pipes passes right under a 2 foot wide A/C duct. The tube won't fit at the top of the pipe since it's too close to the duct. What's the best way to insulate that section? Do a relief cut that's so deep that there's almost no insulation left at the top, but still retaining the jacket (which would probably deform due to almost no insulation left)? Or cut out a inch or two wide, two foot long section at the top of the pipe? Or ... ? Moving the heating pipe, or moving the A/C duct, is NOT an option. Thanks.
Do a relief cut that's so deep that there's almost no insulation left at the top, but still retaining the jacket

There, you answered your own question!

Wildie is offline   Reply With Quote
Old 01-11-2012, 08:17 PM   #3
MarginallyQualified
 
Join Date: Dec 2011
Location: Winston-Salem NC
Posts: 2,553
Default

How to deal with obstruction when insulating pipes?


Quote:
Originally Posted by Rav View Post
I'm insulating hot water heating pipes (black iron pipe) in my basement using 1"-thick-wall jacketed fiberglass tubes. At one point one of the pipes passes right under a 2 foot wide A/C duct. The tube won't fit at the top of the pipe since it's too close to the duct. What's the best way to insulate that section?
If this is an untempered basement...
then the AC duct should be getting insulated as well.
That stuff (R6 duct insulation) is about 1.5" thick.

Somethings got to give.
http://www.youtube.com/watch?v=xAf3FgwPzaI

hth
TarheelTerp is offline   Reply With Quote
Old 01-12-2012, 08:20 AM   #4
Exterior Construction
 
Windows on Wash's Avatar
 
Join Date: Aug 2011
Location: VA, MD, DC
Posts: 3,493
Default

How to deal with obstruction when insulating pipes?


In this area, 95% likely the basement is conditioned.

While I applaud the goal to insulate the pipes, the reality is that they are not costing that much in lost efficiency. For 1/2 the season (heating season) they are helping condition the space.

I would not leave just the jacket on the insulation if it is PVC jacketed. The fiberglass is what is providing the thermal resistance in this case and PVC against a hot pipe is never a good idea.

I would not be too concerned about the lack of insulation in a few spots.

There is much more potential in the home with the repairs on other items (air sealing the attic, bands, etc).
__________________

To view links or images in signatures your post count must be 10 or greater. You currently have 0 posts.



To view links or images in signatures your post count must be 10 or greater. You currently have 0 posts.


Windows on Wash is offline   Reply With Quote
Reply

Tags
insulating, obstruction, pipes


-->
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
Drain Pipes, Walls and Studs mattaparity Plumbing 2 12-18-2011 08:22 AM
How to (retrofit) insulate/air seal cantilever with hot water pipes in it? KatieAK HVAC 5 11-01-2009 09:15 PM
insulating heated garage(retrofit)- insul. & pipes KatieAK Building & Construction 0 10-25-2009 10:03 PM
Insulating Steam Pipes Densec General Discussion 4 10-06-2009 11:42 AM
How to deal with greasy black deposit inside of drain pipes? darsunt Plumbing 4 09-23-2009 08:16 AM


Top of Page | View New Posts


All times are GMT -4. The time now is 03:15 PM.


© 2003 - 2010 The Building Network LLC